View larger
DG1-34046FB-C54C 9702-3105-00P Y7-9702-3105-00P EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, ..
DG1-34046FB-C54C
9702310500P
Y7-9702-3105-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DG1-34046FB-C54C is a robust variable frequency drive utilized for managing three-phase AC motor operations in demanding industrial setups. Variable frequency drives allow operators to tune performance parameters, reduce energy consumption, and extend the lifespan of driven mechanical systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 46 A
- Power consumption (EF000346): 818 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL
CE
RoHS, ISO 9001
EAC
IEC/EN61800-3
UL File No.: E134360
UL report applies to both US and Canada
IEC/EN61800-5
IEC/EN 61800-3
CUL
Specification for general requirements: IEC/EN 61800-2
CSA-C22.2 No. 274-13
UkrSEPRO
UL Category Control No.: NMMS, NMMS7
Certified by UL for use in Canada
Safety requirements: IEC/EN 61800-5
C-Tick
Features & Functions
Tool-less swapping of fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C3 ≤ 50 m, Radio interference level, maximum motor cable length
150 m, screened, maximum permissible, Motor feeder
NEMA 12
Multi-line graphic display
Internal DC link
Additional PCB protection
Radio interference suppression filter
Brake chopper
PC connection
IGBT inverter
DC link choke
Breaking resistance
C1: with external filter, for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Climatic environmental conditions
Max. 3000 m
Above 1000 m with 1 % derating per 100 m
Max. 2000 m for Corner Grounded TN Systems
Main circuit
Sensorless vector control (SLV)
Torque regulation
Speed control with slip compensation
400 V AC, 3-phase
480 V AC, 3-phase
400 V AC, 3-phase
500 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Control circuit
Communication
PROFIBUS, optional
Ethernet IP, built in
BACnet MS/TP, built in
CANopen®, optional
Modbus RTU, built in
Modbus TCP, built in
DeviceNet, optional
Yes
Other bus systems
TCP/IP
PROFIBUS
MODBUS
CAN
BACnet
DeviceNet
EtherNet/IP