View larger
DG1-34031FB-C54C 9702-3101-00P Y7-9702-3101-00P EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, ..
DG1-34031FB-C54C
9702310100P
Y7-9702-3101-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-performance motor management, the Eaton Moeller DG1-34031FB-C54C variable frequency drive delivers exact control over AC motor velocity. Variable frequency drives play a critical role in process automation by optimizing mechanical performance and lowering power draw.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 31 A
- Power consumption (EF000346): 471 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS, ISO 9001
CUL
UL508
IEC/EN61800-3
Certified by UL for use in Canada
EAC
CSA-C22.2 No. 274-13
IEC/EN 61800-3
Specification for general requirements: IEC/EN 61800-2
UkrSEPRO
UL File No.: E134360
CE
UL report applies to both US and Canada
IEC/EN61800-5
Safety requirements: IEC/EN 61800-5
UL Category Control No.: NMMS, NMMS7
UL
Features & Functions
Temperature-controlled fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C3 ≤ 50 m, Radio interference level, maximum motor cable length
C2 ≤ 10 m, Radio interference level, maximum motor cable length
NEMA 12
Control unit
PC connection
Additional PCB protection
DC link choke
Internal DC link
Multi-line graphic display
Breaking resistance
Radio interference suppression filter
IGBT inverter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C1: with external filter, for conducted emissions only
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Climatic environmental conditions
Max. 3000 m
Max. 2000 m for Corner Grounded TN Systems
Max. 1000 m
Main circuit
U/f control
Torque regulation
Sensorless vector control (SLV)
400 V AC, 3-phase
480 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Control circuit
Communication
Ethernet IP, built in
Modbus RTU, built in
BACnet MS/TP, built in
Modbus TCP, built in
CANopen®, optional
DeviceNet, optional
PROFIBUS, optional
Yes
MODBUS
BACnet
CAN
DeviceNet
TCP/IP
PROFIBUS
PROFINET IO
EtherNet/IP