View larger
DG1-34023FB-C54C 9702-2105-00P Y7-9702-2105-00P EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, ..
DG1-34023FB-C54C
9702210500P
Y7-9702-2105-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DG1-34023FB-C54C Eaton Moeller variable frequency drive delivers adjustable motor control for industrial production lines and heavy-duty mechanical equipment. Such frequency converters ensure efficient power conversion and accurate rotational speed regulation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 23 A
- Power consumption (EF000346): 421 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS, ISO 9001
UL File No.: E134360
Certified by UL for use in Canada
UL Category Control No.: NMMS, NMMS7
UL508
UL
UkrSEPRO
C-Tick
CE
CSA-C22.2 No. 274-13
CUL
Specification for general requirements: IEC/EN 61800-2
UL report applies to both US and Canada
IEC/EN 61800-3
IEC/EN61800-5
Safety requirements: IEC/EN 61800-5
EAC
Features & Functions
Tool-less swapping of fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
150 m, screened, maximum permissible, Motor feeder
C3 ≤ 50 m, Radio interference level, maximum motor cable length
NEMA 12
PC connection
IGBT inverter
DC link choke
Brake chopper
Multi-line graphic display
Internal DC link
Control unit
Additional PCB protection
Breaking resistance
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 1000 m
Max. 2000 m for Corner Grounded TN Systems
Main circuit
Speed control with slip compensation
U/f control
Torque regulation
400 V AC, 3-phase
500 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 % (I/Ie), DC - Main circuit
Adjustable to 150 %, DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Control circuit
Communication
SmartWire-DT, optional
Ethernet IP, built in
DeviceNet, optional
PROFIBUS, optional
Modbus RTU, built in
Modbus TCP, built in
BACnet MS/TP, built in
In conjunction with DXG-NET-SWD SmartWire DT module
CAN
TCP/IP
PROFINET IO
Other bus systems
BACnet
MODBUS
DeviceNet
EtherNet/IP