View larger
DG1-34016FB-C54C 9702-2103-00P Y7-9702-2103-00P EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, ..
DG1-34016FB-C54C
9702210300P
Y7-9702-2103-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DG1-34016FB-C54C variable frequency drive systems provide dependable speed regulation for three-phase industrial motors. Industrial facilities rely on these robust controllers to optimize torque profiles, protect equipment from mechanical strain, and maintain consistent process outputs.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 16 A
- Power consumption (EF000346): 293 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
CUL
CE
C-Tick
Certified by UL for use in Canada
UL508
CSA-C22.2 No. 274-13
Safety requirements: IEC/EN 61800-5
Specification for general requirements: IEC/EN 61800-2
UL File No.: E134360
UL report applies to both US and Canada
IEC/EN 61800-3
IEC/EN61800-5
UL
RoHS, ISO 9001
UL Category Control No.: NMMS, NMMS7
UkrSEPRO
Features & Functions
Tool-less swapping of fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C3 ≤ 50 m, Radio interference level, maximum motor cable length
IP54
DC link choke
Additional PCB protection
Radio interference suppression filter
Breaking resistance
Internal DC link
Control unit
PC connection
Multi-line graphic display
IGBT inverter
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Mechanical, According to EN 61800-5-1, IEC/EN 60068-2-27
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 2000 m for Corner Grounded TN Systems
Above 1000 m with 1 % derating per 100 m
Max. 1000 m
Main circuit
Speed control with slip compensation
Sensorless vector control (SLV)
U/f control
500 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Adjustable to 150 %, DC - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Control circuit
Communication
Modbus TCP, built in
DeviceNet, optional
Modbus RTU, built in
BACnet MS/TP, built in
Ethernet IP, built in
PROFIBUS, optional
CANopen®, optional
In conjunction with DXG-NET-SWD SmartWire DT module
DeviceNet
TCP/IP
PROFIBUS
CAN
PROFINET IO
BACnet
Other bus systems
EtherNet/IP