Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A high-performance Eaton Moeller variable frequency drive, designated as DG1-326D6FB-C54C, regulates motor dynamics across complex mechanical configurations. Industrial facilities deploy drives of this class to match motor speeds with real-time operational demands, yielding higher efficiency and safeguarding equipment from excessive startup currents.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 208 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 240 V
- Nominal output current I2N (EF009561): 6.6 A
- Power consumption (EF000346): 89 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-5
CE
Certified by UL for use in Canada
UL508
IEC/EN 61800-3
RoHS, ISO 9001
EAC
UL
UL File No.: E134360
IEC/EN61800-3
Safety requirements: IEC/EN 61800-5
Specification for general requirements: IEC/EN 61800-2
UL Category Control No.: NMMS, NMMS7
UL report applies to both US and Canada
C-Tick
CUL
UkrSEPRO
Features & Functions
Tool-less swapping of fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
100 m, screened, maximum permissible, Motor feeder
C2 ≤ 10 m, Radio interference level, maximum motor cable length
IP54
IGBT inverter
PC connection
DC link choke
Control unit
Multi-line graphic display
Breaking resistance
Radio interference suppression filter
Brake chopper
Internal DC link
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C1: with external filter, for conducted emissions only
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
UPS drop test (for weights inside the UPS frame)
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 2000 m for Corner Grounded TN Systems
Max. 1000 m
Main circuit
Speed control with slip compensation
Torque regulation
Sensorless vector control (SLV)
230 V AC, 3-phase
240 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 30 % MN, Standard - Main circuit
Control circuit
Communication
DeviceNet, optional
PROFIBUS, optional
CANopen®, optional
Modbus TCP, built in
SmartWire-DT, optional
BACnet MS/TP, built in
Modbus RTU, built in
Yes
MODBUS
PROFINET IO
CAN
BACnet
Other bus systems
DeviceNet
PROFIBUS
EtherNet/IP