View larger
DG1-32061FN-C21C 9701-4004-00P Y7-9701-4004-00P EATON ELECTRIC DG1-32061FN-C21C Variable frequency drive, 3-..
DG1-32061FN-C21C
9701400400P
Y7-9701-4004-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Eaton Moeller DG1-32061FN-C21C variable frequency drive provides high-capacity speed regulation for industrial electric motors, ensuring efficient operation and process control.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 208 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 400 Hz
- Max. output voltage: 240 V
- Nominal output current I2N: 61 A
- Power consumption: 689 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 2
- Number of analogue inputs: 2
- Number of digital outputs: 1
- Number of digital inputs: 8
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
EAC
Safety requirements: IEC/EN 61800-5
CE
Specification for general requirements: IEC/EN 61800-2
UL File No.: E134360
CUL
IEC/EN61800-5
UkrSEPRO
C-Tick
UL508
Certified by UL for use in Canada
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3
IEC/EN61800-3
RoHS, ISO 9001
CSA-C22.2 No. 274-13
UL report applies to both US and Canada
Features & Functions
Externally accessible fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C3 ≤ 50 m, Radio interference level, maximum motor cable length
200 m, screened, maximum permissible, Motor feeder
NEMA 1
Radio interference suppression filter
Multi-line graphic display
Internal DC link
IGBT inverter
DC link choke
Additional PCB protection
PC connection
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C1: with external filter, for conducted emissions only
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 150 Hz, According to EN 61800-5-1, IEC/EN 60068-2-6
Climatic environmental conditions
Max. 2000 m for Corner Grounded TN Systems
Max. 3000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
U/f control
Torque regulation
Sensorless vector control (SLV)
230 V AC, 3-phase
240 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 150 %, DC - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Control circuit
Communication
Modbus TCP, built in
BACnet MS/TP, built in
Ethernet IP, built in
PROFIBUS, optional
DeviceNet, optional
SmartWire-DT, optional
CANopen®, optional
In conjunction with DXG-NET-SWD SmartWire DT module
Other bus systems
MODBUS
DeviceNet
CAN
TCP/IP
PROFIBUS
PROFINET IO
EtherNet/IP