View larger
DG1-32011FB-C54C 9701-1109-00P Y7-9701-1109-00P EATON ELECTRIC DG1-32011FB-C54C Variable frequency drive, 3-..
DG1-32011FB-C54C
9701110900P
Y7-9701-1109-00P
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A variable frequency drive such as the Eaton Moeller DG1-32011FB-C54C regulates the speed and torque output of industrial alternating current motors. Speed controllers are essential in automated environments to maintain exact operational tempos and reduce electrical surges during startup phases.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 208 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 400 Hz
- Max. output voltage (EF009560): 240 V
- Nominal output current I2N (EF009561): 11 A
- Power consumption (EF000346): 129 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 8
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL
C-Tick
Specification for general requirements: IEC/EN 61800-2
UL File No.: E134360
UL Category Control No.: NMMS, NMMS7
UL508
CUL
Certified by UL for use in Canada
EAC
Safety requirements: IEC/EN 61800-5
CSA-C22.2 No. 274-13
IEC/EN 61800-3
IEC/EN61800-3
UL report applies to both US and Canada
RoHS, ISO 9001
UkrSEPRO
CE
Features & Functions
Temperature-controlled fan
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: Power Xpert inControl
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
100 m, screened, maximum permissible, Motor feeder
NEMA 12
Internal DC link
PC connection
IGBT inverter
Brake chopper
Control unit
Breaking resistance
Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
C1: with external filter, for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging)
Resistance: 15.8 – 150 Hz, 1 g, Maximum acceleration amplitude
Resistance: 5 - 15.8 Hz, Amplitude 1 mm (peak)
Climatic environmental conditions
Max. 1000 m
Max. 3000 m
Max. 2000 m for Corner Grounded TN Systems
Main circuit
Torque regulation
U/f control
Sensorless vector control (SLV)
240 V AC, 3-phase
240 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Adjustable to 150 % (I/Ie), DC - Main circuit
Max. 30 % MN, Standard - Main circuit
Control circuit
Communication
SmartWire-DT, optional
BACnet MS/TP, built in
Modbus RTU, built in
DeviceNet, optional
CANopen®, optional
PROFIBUS, optional
Ethernet IP, built in
In conjunction with DXG-NET-SWD SmartWire DT module
MODBUS
DeviceNet
CAN
PROFIBUS
PROFINET IO
BACnet
Other bus systems
EtherNet/IP