Designed for compact machine automation, the DE11-345D0FN-N20N Eaton Moeller variable speed starter operates as an efficient drive solution for controlling three-phase electric motors. Variable speed starters combine the simplicity of motor starters with basic frequency conversion to regulate motor speeds smoothly. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5 A
- Power consumption (EF000346): 65 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-3
UL
IEC/EN61800-5
IEC/EN61800-3
RoHS, ISO 9001
RCM
CUL
UL 508C
UL report applies to both US and Canada
Certified by UL for use in Canada
CE
CSA-C22.2 No. 14
Specification for general requirements: IEC/EN 61800-2
Safety requirements: IEC/EN 61800-5-1
UL File No.: E172143
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
PC connection
PC connection
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
CANopen®, built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
MODBUS
Other bus systems
CAN
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
< 3.5 mA (AC-operated)
U/f control
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit