View larger
DE11-129D6FN-N20N 180655 Y7-180655 EATON ELECTRIC Variable speed starters, Rated operational voltage 230 V A..
DE11-129D6FN-N20N
180655
Y7-180655
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DE11-129D6FN-N20N variable speed starter delivers reliable starting and continuous speed adjustment for standard industrial motors. These robust controllers bridge the gap between traditional motor starters and advanced inverters, offering streamlined operation for production machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 9.6 A
- Power consumption (EF000346): 105 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 508C
UL report applies to both US and Canada
Safety requirements: IEC/EN 61800-5-1
CE
UL
RoHS, ISO 9001
IEC/EN61800-3
RCM
IEC/EN 61800-3
CUL
Specification for general requirements: IEC/EN 61800-2
UL Category Control No.: NMMS, NMMS7
CSA-C22.2 No. 14
UL File No.: E172143
IEC/EN61800-5
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
PC connection
General
C3 ≤ 25 m, Radio interference level, maximum motor cable length
C2 ≤ 10 m, Radio interference level, maximum motor cable length
CANopen®, built in
OP-Bus (RS485), built in
Yes
NEMA Other
MODBUS
EtherNet/IP
CAN
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
< 10 mA (DC-operated)
Speed control with slip compensation
230 V AC, 3-phase
240 V AC, 1-phase
Motor rating
Apparent power
Braking function
Adjustable to 100 %, DC - Main circuit