View larger
DE11-127D0FN-N20N 180654 Y7-180654 EATON ELECTRIC Variable speed starters, Rated operational voltage 230 V A..
DE11-127D0FN-N20N
180654
Y7-180654
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DE11-127D0FN-N20N variable speed starter serves as a simplified motor controller designed to adjust rotational speeds and protect machinery without the complexity of traditional drives. These compact components are commonly integrated into pumps, fans, and conveyors to improve operational efficiency.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 7 A
- Power consumption (EF000346): 59 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL report applies to both US and Canada
RCM
Safety requirements: IEC/EN 61800-5-1
UL
IEC/EN61800-5
CSA-C22.2 No. 14
Specification for general requirements: IEC/EN 61800-2
UL File No.: E172143
IEC/EN61800-3
CE
Certified by UL for use in Canada
RoHS, ISO 9001
IEC/EN 61800-3
CUL
UL Category Control No.: NMMS, NMMS7
Global
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
PC connection
Features & Functions
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C1 ≤ 5 m, Radio interference level, maximum motor cable length
OP-Bus (RS485), built in
CANopen®, built in
Yes
NEMA Other
EtherNet/IP
Other bus systems
CAN
C1: for conducted emissions only
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
General
Above 1000 m with 1 % derating per 100 m
Climatic environmental conditions
< 10 mA (DC-operated)
U/f control
240 V AC, 3-phase
240 V AC, 1-phase
Main circuit
Motor rating
Apparent power
Adjustable to 100 %, DC - Main circuit