View larger
DE11-122D3NN-N20N 180657 Y7-180657 EATON ELECTRIC Variable speed starter, Rated operational voltage 230 V AC..
DE11-122D3NN-N20N
180657
Y7-180657
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable speed starter, part number DE11-122D3NN-N20N, regulates motor velocity in automation setups to optimize process output and mechanical efficiency. These units are deployed extensively across manufacturing machinery, conveyor networks, and pump systems where precise operational speed control is required.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 2.3 A
- Power consumption (EF000346): 20 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL Category Control No.: NMMS, NMMS7
UL report applies to both US and Canada
RCM
Certified by UL for use in Canada
CUL
IEC/EN 61800-3
UL 508C
CSA-C22.2 No. 14
CE
IEC/EN61800-3
UL
UL File No.: E172143
RoHS, ISO 9001
Safety requirements: IEC/EN 61800-5-1
IEC/EN61800-5
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
General
C1 ≤ 5 m, Radio interference level, maximum motor cable length
C2 ≤ 10 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
OP-Bus (RS485), built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
Other bus systems
MODBUS
CAN
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
C1: for conducted emissions only
Climatic environmental conditions
Max. 2000 m
Main circuit
< 3.5 mA (AC-operated)
U/f control
240 V AC, 3-phase
230 V AC, 1-phase
Motor rating
Apparent power
Braking function
Adjustable to 100 %, DC - Main circuit