Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable speed starter, model DE1-343D6FN-N20N, is engineered to regulate motor speeds efficiently within manufacturing machinery and conveyor systems. Devices of this type provide reliable acceleration and deceleration control for industrial electric motors to optimize operational cycles.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 3.6 A
- Power consumption (EF000346): 47 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Specification for general requirements: IEC/EN 61800-2
CSA-C22.2 No. 14
UL Category Control No.: NMMS, NMMS7
UL 508C
CE
Certified by UL for use in Canada
IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5-1
CUL
RCM
UL
IEC/EN61800-5
UL report applies to both US and Canada
IEC/EN61800-3
UL File No.: E172143
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Radio interference suppression filter
Radio interference suppression filter
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
Yes
NEMA Other
Other bus systems
EtherNet/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 2000 m
Main circuit
< 10 mA (DC-operated)
U/f control
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit