DE1-124D3NN-N20N 177362 Y7-177362 EATON ELECTRIC Variable speed starter, Rated operational voltage 230 V AC,..
DE1-124D3NN-N20N
177362
Y7-177362
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable speed starter (DE1-124D3NN-N20N) bridges the gap between traditional motor starters and full frequency converters by offering straightforward speed adjustments for basic industrial applications. These starters are commonly used on simple material handling systems, fans, and pumps where advanced programming is unnecessary.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 32 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Specification for general requirements: IEC/EN 61800-2
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-3
CUL
Safety requirements: IEC/EN 61800-5-1
Certified by UL for use in Canada
CE
UL 508C
IEC/EN61800-5
IEC/EN 61800-3
CSA-C22.2 No. 14
RoHS, ISO 9001
UL report applies to both US and Canada
UL File No.: E172143
UL
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
General
C1 ≤ 5 m, Radio interference level, maximum motor cable length
C2 ≤ 10 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
Other bus systems
EtherNet/IP
C1: for conducted emissions only
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 2000 m
Main circuit
< 3.5 mA (AC-operated)
U/f control
240 V AC, 3-phase
230 V AC, 1-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit