View larger
DE1-124D3FN-N20N 174330 Y7-174330 EATON ELECTRIC Variable speed starter, Rated operational voltage 230 V AC,..
DE1-124D3FN-N20N
174330
Y7-174330
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Variable speed starters offer streamlined motor control by facilitating smooth acceleration and deceleration profiles without the complexity of full inverters. Technicians deploy these units in basic material handling gear, conveyor belts, and light industrial machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 32 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CSA-C22.2 No. 14
CUL
IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5-1
UL File No.: E172143
Certified by UL for use in Canada
IEC/EN61800-5
UL Category Control No.: NMMS, NMMS7
UL 508C
CE
RCM
IEC/EN61800-3
Specification for general requirements: IEC/EN 61800-2
RoHS, ISO 9001
UL
Global
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
PC connection
Features & Functions
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C3 ≤ 25 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
EtherNet/IP
Other bus systems
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
General
Above 1000 m with 1 % derating per 100 m
Climatic environmental conditions
< 3.5 mA (AC-operated)
U/f control
230 V AC, 3-phase
240 V AC, 1-phase
Main circuit
Motor rating
Apparent power
Adjustable to 100 %, DC - Main circuit