View larger
DE1-121D4NN-N20N 177359 Y7-177359 EATON ELECTRIC Variable speed starter, Rated operational voltage 230 V AC,..
DE1-121D4NN-N20N
177359
Y7-177359
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller variable speed starter (DE1-121D4NN-N20N) bridges the operational gap between traditional motor starters and full frequency inverters, offering simplified speed control for basic drive tasks. These units improve system adaptability without complex programming.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 1.4 A
- Power consumption (EF000346): 17 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
RoHS, ISO 9001
UL report applies to both US and Canada
UL File No.: E172143
CSA-C22.2 No. 14
Specification for general requirements: IEC/EN 61800-2
CUL
UL Category Control No.: NMMS, NMMS7
CE
UL 508C
Certified by UL for use in Canada
IEC/EN61800-5
Safety requirements: IEC/EN 61800-5-1
IEC/EN 61800-3
UL
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C3 ≤ 25 m, Radio interference level, maximum motor cable length
OP-Bus (RS485), built in
Yes
NEMA Other
MODBUS
Other bus systems
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
< 10 mA (DC-operated)
Speed control with slip compensation
230 V AC, 3-phase
240 V AC, 1-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit