View larger
DE1-121D4FN-N20N 174327 Y7-174327 EATON ELECTRIC Variable speed starter, Rated operational voltage 230 V AC,..
DE1-121D4FN-N20N
174327
Y7-174327
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as an Eaton Moeller variable speed starter, part DE1-121D4FN-N20N provides streamlined motor control and operational protection for basic industrial drive tasks. Such units simplify machine integration by combining soft-starting capabilities with straightforward speed adjustment for smaller electric motors.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 300 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 1.4 A
- Power consumption (EF000346): 17 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 1
- Number of digital outputs (EF001993): 0
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
IEC/EN61800-5
UL
Specification for general requirements: IEC/EN 61800-2
IEC/EN 61800-3
UL File No.: E172143
CUL
Safety requirements: IEC/EN 61800-5-1
UL report applies to both US and Canada
UL 508C
CSA-C22.2 No. 14
UL Category Control No.: NMMS, NMMS7
Certified by UL for use in Canada
RCM
RoHS, ISO 9001
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Radio interference suppression filter
Radio interference suppression filter
General
C2 ≤ 10 m, Radio interference level, maximum motor cable length
C1 ≤ 5 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
Yes
NEMA Other
EtherNet/IP
MODBUS
C1: for conducted emissions only
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
< 10 mA (DC-operated)
Speed control with slip compensation
240 V AC, 3-phase
240 V AC, 1-phase
Motor rating
Apparent power
Braking function
Adjustable to 100 %, DC - Main circuit