Eaton Moeller DC1-S24D3FN-A6SOE1 is a frequency converter engineered to regulate motor speed in industrial machinery. Drive units of this type are widely deployed across manufacturing plants to optimize conveyor belts, pumps, and fans by matching motor output to exact process demands.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 200 V
- Mains frequency: 50/60 Hz
- Number of phases input: 1
- Number of phases output: 1
- Max. output frequency: 500 Hz
- Max. output voltage: 250 V
- Nominal output current I2N: 4.3 A
- Power consumption: 45.75 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 1
- Number of analogue inputs: 2
- Number of digital outputs: 1
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
EAC
CE
UkrSEPRO
UL File No.: E172143
CE marking
IEC/EN 61800-2
IEC/EN 61800-3
UL 508C
IEC/EN 61800-5-1
UL Category Control No.: NMMS, NMMS7
UL
UL Listed
UL report applies to both US and Canada
RCM
CSA-C22.2 No. 14
IEC/EN61800-5
RoHS, ISO 9001
Certified by UL for use in Canada
Features & Functions
Parameterization: drivesConnect
Parameterization: Keypad
Parameterization: drivesConnect mobile (App)
UV resistance
7-digital display assembly
PC connection
Radio interference suppression filter
Control unit
Additional PCB protection
IGBT inverter
Internal DC link
General
50 m, screened, maximum permissible, Motor feeder
C3 ≤ 25 m, maximum motor cable length
150 m, unscreened, with motor choke, maximum permissible, Motor feeder
C1 ≤ 1 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length
100 m, screened, with motor choke, maximum permissible, Motor feeder
OP-Bus (RS485), built in
SmartWire-DT, optional
Modbus RTU, built in
IP66
MODBUS
CAN
Other bus systems
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
PM motors
Sensorless vector control (SLV)
BLDC motors
Synchronous reluctance motors
Speed control with slip compensation
240 V AC, single-phase
240 V AC, 1-phase