View larger
DC1-S2011FB-A66OE1 199391 Y7-199391 EATON ELECTRIC DC1-S2011FB-A66OE1
DC1-S2011FB-A66OE1
199391
Y7-199391
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DC1-S2011FB-A66OE1 is a specialized variable frequency drive utilized to control motor velocity and output characteristics in electrical systems. Such drives help maintain consistent operational performance while protecting machinery from fluctuating loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 1
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 11 A
- Power consumption (EF000346): 103.4 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
EAC
UL Listed
UL 508C
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3
Certified by UL for use in Canada
UL report applies to both US and Canada
CE
RCM
CUL
IEC/EN61800-5
RoHS, ISO 9001
CE marking
UL
UkrSEPRO
IEC/EN 61800-2
CSA-C22.2 No. 14
Features & Functions
Parameterization: Fieldbus
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad
Radio interference suppression filter
IGBT inverter
Internal DC link
UV resistance
Control unit
7-digital display assembly
Additional PCB protection
Breaking resistance
PC connection
General
C3 ≤ 25 m, maximum motor cable length
C2 ≤ 5 m, maximum motor cable length
100 m, screened, maximum permissible cable length
200 m, screened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
C1 ≤ 1 m, maximum motor cable length
OP-Bus (RS485), built in
Modbus RTU, built in
SmartWire-DT, optional
NEMA 4X
CAN
MODBUS
Other bus systems
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Main circuit
BLDC motors
U/f control
Synchronous reluctance motors
PM motors
Sensorless vector control (SLV)
240 V AC, single-phase
240 V AC, 1-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit