View larger
DC1-349D5NB-A20CE1 185733 Y7-185733 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 9.5 A, 4 kW,..
DC1-349D5NB-A20CE1
185733
Y7-185733
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DC1-349D5NB-A20CE1 operates as a variable frequency drive that allows precise electronic control over motor velocity and torque characteristics. Plant operators rely on these devices to minimize mechanical wear and optimize fluid or material movement across automated production lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 380 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 500 V
- Nominal output current I2N: 9.5 A
- Power consumption: 136 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 1
- Number of analogue inputs: 2
- Number of digital outputs: 1
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
UL Category Control No.: NMMS, NMMS7
Specification for general requirements: IEC/EN 61800-2
UL
UL 508C
IEC/EN 61800-3
RoHS, ISO 9001
EAC
UL report applies to both US and Canada
CUL
RCM
Safety requirements: IEC/EN 61800-5-1
UkrSEPRO
UL File No.: E172143
CSA-C22.2 No. 14
IEC/EN61800-3
CE
Certified by UL for use in Canada
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
PC connection
Control unit
Breaking resistance
Brake chopper
IGBT inverter
7-digital display assembly
Additional PCB protection
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
OP-Bus (RS485), built in
CANopen®, built in
Modbus RTU, built in
Yes
NEMA Other
Other bus systems
CAN
EtherNet/IP
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
U/f control
Sensorless vector control (SLV)
BLDC motors
PM motors
Synchronous reluctance motors
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit