View larger
DC1-349D5FB-A6SOE1 199438 Y7-199438 EATON ELECTRIC DC1-349D5FB-A6SOE1
DC1-349D5FB-A6SOE1
199438
Y7-199438
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DC1-349D5FB-A6SOE1 is a reliable variable frequency drive built to manage motor speeds and improve electrical system performance in commercial and industrial settings. Variable frequency drives are standard components in automation systems, enabling smooth acceleration, decelerations, and precise process regulation for electric motors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 9.5 A
- Power consumption (EF000346): 136 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL Listed
RCM
Certified by UL for use in Canada
CUL
CSA-C22.2 No. 14
IEC/EN 61800-2
IEC/EN 61800-3
UL report applies to both US and Canada
UkrSEPRO
UL File No.: E172143
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-5
IEC/EN 61800-5-1
UL 508C
RoHS, ISO 9001
CE marking
UL
EAC
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Parameterization: Keypad
Internal DC link
UV resistance
Additional PCB protection
Breaking resistance
7-digital display assembly
IGBT inverter
Control unit
Local controls
PC connection
Brake chopper
General
150 m, unscreened, maximum permissible cable length
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible cable length
200 m, screened, with motor choke, maximum permissible cable length
C2 ≤ 5 m, maximum motor cable length
OP-Bus (RS485), built in
CANopen®, built in
Modbus RTU, built in
NEMA 4X
Other bus systems
CAN
MODBUS
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Main circuit
Speed control with slip compensation
U/f control
Sensorless vector control (SLV)
BLDC motors
PM motors
400 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit