View larger
DC1-349D5FB-A20CE1 185755 Y7-185755 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 9.5 A, 4 kW,..
DC1-349D5FB-A20CE1
185755
Y7-185755
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable frequency drive, identified as model DC1-349D5FB-A20CE1, controls motor speed by converting fixed incoming line frequency into adjustable output signals. Industrial drive systems are commonly utilized to optimize material handling equipment and pump performance.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 9.5 A
- Power consumption (EF000346): 136 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Safety requirements: IEC/EN 61800-5-1
UL report applies to both US and Canada
CE
CUL
RoHS, ISO 9001
Certified by UL for use in Canada
UL
CSA-C22.2 No. 14
UkrSEPRO
UL 508C
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-3
RCM
IEC/EN61800-5
UL File No.: E172143
EAC
Specification for general requirements: IEC/EN 61800-2
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Brake chopper
Control unit
Radio interference suppression filter
PC connection
Internal DC link
Breaking resistance
7-digital display assembly
Additional PCB protection
General
150 m, unscreened, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
100 m, screened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
SmartWire-DT, optional
CANopen®, built in
OP-Bus (RS485), built in
Yes
NEMA Other
Other bus systems
CAN
MODBUS
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Main circuit
Speed control with slip compensation
Sensorless vector control (SLV)
BLDC motors
PM motors
Synchronous reluctance motors
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit