View larger
DC1-344D1FB-A66OE1 199433 Y7-199433 EATON ELECTRIC DC1-344D1FB-A66OE1
DC1-344D1FB-A66OE1
199433
Y7-199433
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as a compact frequency converter, the Eaton Moeller DC1-344D1FB-A66OE1 unit regulates motor speeds to optimize mechanical operations within industrial automation setups. Such converters improve system efficiency and extend equipment lifespan by eliminating abrupt mechanical shocks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.1 A
- Power consumption (EF000346): 66.5 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CSA-C22.2 No. 14
IEC/EN 61800-5-1
UL Listed
Certified by UL for use in Canada
UL report applies to both US and Canada
UkrSEPRO
IEC/EN 61800-3
UL File No.: E172143
CE marking
CE
UL
IEC/EN61800-5
UL Category Control No.: NMMS, NMMS7
CUL
RCM
RoHS, ISO 9001
IEC/EN 61800-2
UL 508C
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: drivesConnect
Brake chopper
Control unit
7-digital display assembly
Internal DC link
PC connection
IGBT inverter
UV resistance
Breaking resistance
Additional PCB protection
General
C2 ≤ 5 m, maximum motor cable length
100 m, screened, maximum permissible cable length
200 m, screened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
C3 ≤ 25 m, maximum motor cable length
OP-Bus (RS485), built in
CANopen®, built in
SmartWire-DT, optional
IP66
CAN
MODBUS
EtherNet/IP
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 4000 m
Main circuit
PM motors
U/f control
Speed control with slip compensation
Sensorless vector control (SLV)
Synchronous reluctance motors
400 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 30 % MN, Standard - Main circuit