View larger
DC1-342D2FN-A66OE1 199429 Y7-199429 EATON ELECTRIC DC1-342D2FN-A66OE1
DC1-342D2FN-A66OE1
199429
Y7-199429
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed to deliver versatile motor control, the Eaton Moeller DC1-342D2FN-A66OE1 frequency converter manages AC motor velocity to optimize automated manufacturing tasks. Industrial facilities install these drives to reduce energy consumption and improve mechanical response times across diverse production lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.2 A
- Power consumption (EF000346): 33.75 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL Category Control No.: NMMS, NMMS7
EAC
IEC/EN61800-5
UL
RoHS, ISO 9001
CE marking
UL File No.: E172143
IEC/EN 61800-3
UL 508C
UL report applies to both US and Canada
IEC/EN 61800-2
UkrSEPRO
CE
Certified by UL for use in Canada
CSA-C22.2 No. 14
CUL
UL Listed
IEC/EN 61800-5-1
Features & Functions
Parameterization: Fieldbus
Parameterization: Keypad
Parameterization: drivesConnect
IGBT inverter
Radio interference suppression filter
7-digital display assembly
UV resistance
PC connection
Internal DC link
Additional PCB protection
General
C3 ≤ 25 m, maximum motor cable length
50 m, screened, maximum permissible, Motor feeder
100 m, screened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, maximum motor cable length
150 m, unscreened, with motor choke, maximum permissible, Motor feeder
CANopen®, built in
SmartWire-DT, optional
OP-Bus (RS485), built in
IP66
Other bus systems
EtherNet/IP
CAN
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
Sensorless vector control (SLV)
Synchronous reluctance motors
U/f control
Speed control with slip compensation
PM motors
400 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit