View larger
DC1-342D2FN-A66CE1 185744 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 2.2 A, 0.75 kW, IP66/N..
DC1-342D2FN-A66CE1
185744
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Regulating motor velocity and torque in automated systems, the Eaton Moeller DC1-342D2FN-A66CE1 variable frequency drive provides reliable conversion for three-phase electrical loads. Inverters of this type are widely deployed in manufacturing plants to improve dynamic response, reduce mechanical wear, and enhance operational control of pumps, fans, and conveyors.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 60 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.2 A
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
- Supporting protocol for TCP/IP (EF003050): No
More info
▲General specifications
Certified by UL for use in Canada
CSA-C22.2 No. 14
Safety requirements: IEC/EN 61800-5-1
Specification for general requirements: IEC/EN 61800-2
UkrSEPRO
IEC/EN 61800-3
RCM
UL 508C
UL File No.: E172143
CE
CUL
EAC
UL report applies to both US and Canada
IEC/EN61800-5
UL Category Control No.: NMMS, NMMS7
RoHS, ISO 9001
UL
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Control unit
IGBT inverter
Internal DC link
Radio interference suppression filter
PC connection
Additional PCB protection
General
100 m, screened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
50 m, screened, maximum permissible, Motor feeder
C3 ≤ 25 m, Radio interference level, maximum motor cable length
150 m, unscreened, with motor choke, maximum permissible, Motor feeder
OP-Bus (RS485), built in
CANopen®, built in
SmartWire-DT, optional
NEMA 4X
EtherNet/IP
CAN
Other bus systems
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
Speed control with slip compensation
Sensorless vector control (SLV)
BLDC motors
PM motors
Synchronous reluctance motors
480 V AC, 3-phase
At a switching frequency of 16 kHz and an ambient air temperature of +40 °C
480 V AC, 3-phase
50/60 Hz
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Control circuit
2
4
1