Eaton Moeller DC1-342D2FN-A20CE1 is a variable frequency drive implemented in industrial machinery to control motor output frequencies and operational speeds. Such converters help facilities achieve precise movement control, lower energy consumption, and extend the lifespan of mechanical assets.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.2 A
- Power consumption (EF000346): 63.75 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Safety requirements: IEC/EN 61800-5-1
CUL
UkrSEPRO
UL 508C
Certified by UL for use in Canada
IEC/EN61800-5
UL File No.: E172143
UL Category Control No.: NMMS, NMMS7
EAC
UL report applies to both US and Canada
RoHS, ISO 9001
IEC/EN 61800-3
RCM
UL
CE
CSA-C22.2 No. 14
Specification for general requirements: IEC/EN 61800-2
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
7-digital display assembly
Internal DC link
Control unit
Radio interference suppression filter
IGBT inverter
Additional PCB protection
General
C3 ≤ 25 m, Radio interference level, maximum motor cable length
75 m, unscreened, maximum permissible, Motor feeder
150 m, unscreened, with motor choke, maximum permissible, Motor feeder
50 m, screened, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
CANopen®, built in
SmartWire-DT, optional
Yes
NEMA Other
MODBUS
EtherNet/IP
Other bus systems
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
Speed control with slip compensation
Sensorless vector control (SLV)
BLDC motors
PM motors
Synchronous reluctance motors
400 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit