View larger
DC1-34046FB-A6SOE1 199450 Y7-199450 EATON ELECTRIC DC1-34046FB-A6SOE1
DC1-34046FB-A6SOE1
199450
Y7-199450
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Eaton Moeller DC1-34046FB-A6SOE1 variable frequency drive functions as an adjustable speed controller for industrial electric motors, dynamically modulating frequency and voltage to match load requirements.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 380 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 500 V
- Nominal output current I2N: 46 A
- Power consumption: 801 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 1
- Number of analogue inputs: 2
- Number of digital outputs: 1
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
CSA-C22.2 No. 14
UL Category Control No.: NMMS, NMMS7
UkrSEPRO
UL File No.: E172143
CE
EAC
IEC/EN 61800-3
RoHS, ISO 9001
CUL
IEC/EN 61800-2
UL 508C
IEC/EN61800-5
Certified by UL for use in Canada
UL
RCM
IEC/EN 61800-5-1
UL Listed
UL report applies to both US and Canada
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Parameterization: Keypad
IGBT inverter
Breaking resistance
Brake chopper
Additional PCB protection
Local controls
Internal DC link
PC connection
7-digital display assembly
Radio interference suppression filter
UV resistance
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, maximum motor cable length
100 m, screened, maximum permissible cable length
200 m, screened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
SmartWire-DT, optional
Modbus RTU, built in
OP-Bus (RS485), built in
IP66
CAN
EtherNet/IP
MODBUS
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 4000 m
Main circuit
U/f control
Synchronous reluctance motors
Sensorless vector control (SLV)
BLDC motors
PM motors
480 V AC, 3-phase
400 V AC, 3-phase