View larger
DC1-34024FB-A20CE1 185764 Y7-185764 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 24 A, 11 kW,..
DC1-34024FB-A20CE1
185764
Y7-185764
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DC1-34024FB-A20CE1 variable frequency drive manages motor speed in automation systems by altering input power frequency and voltage. These electronic devices regulate asynchronous motors across manufacturing lines, pumps, and conveyor setups to optimize mechanical performance and energy consumption.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 24 A
- Power consumption (EF000346): 297 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UkrSEPRO
EAC
RCM
CSA-C22.2 No. 14
IEC/EN61800-3
Specification for general requirements: IEC/EN 61800-2
UL report applies to both US and Canada
Certified by UL for use in Canada
RoHS, ISO 9001
UL
IEC/EN61800-5
UL File No.: E172143
IEC/EN 61800-3
UL 508C
Safety requirements: IEC/EN 61800-5-1
CUL
UL Category Control No.: NMMS, NMMS7
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Internal DC link
7-digital display assembly
Radio interference suppression filter
IGBT inverter
PC connection
Breaking resistance
Control unit
Additional PCB protection
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
C3 ≤ 25 m, Radio interference level, maximum motor cable length
100 m, screened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
OP-Bus (RS485), built in
Modbus RTU, built in
CANopen®, built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
EtherNet/IP
MODBUS
CAN
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
U/f control
Speed control with slip compensation
BLDC motors
PM motors
Synchronous reluctance motors
480 V AC, 3-phase
At a switching frequency of 8 kHz and an ambient air temperature of +50 °C
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 30 % MN, Standard - Main circuit