DC1-34018FB-A66OE1
199441
Y7-199441
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The DC1-34018FB-A66OE1 Eaton Moeller variable frequency drive provides efficient electronic motor speed adjustment for commercial and industrial automation systems. Inverters of this category improve system reliability and precision by regulating voltage and frequency inputs to rotating equipment. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 18 A
- Power consumption (EF000346): 304 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-2
UkrSEPRO
RCM
Certified by UL for use in Canada
RoHS, ISO 9001
IEC/EN 61800-5-1
UL Listed
UL
UL 508C
CSA-C22.2 No. 14
UL File No.: E172143
EAC
UL report applies to both US and Canada
CE
CE marking
IEC/EN61800-5
CUL
UL Category Control No.: NMMS, NMMS7
Features & Functions
Parameterization: Keypad
Parameterization: drivesConnect
Parameterization: Fieldbus
PC connection
Breaking resistance
UV resistance
7-digital display assembly
IGBT inverter
Control unit
Additional PCB protection
Brake chopper
Internal DC link
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible cable length
C2 ≤ 5 m, maximum motor cable length
150 m, unscreened, maximum permissible cable length
C3 ≤ 25 m, maximum motor cable length
CANopen®, built in
OP-Bus (RS485), built in
SmartWire-DT, optional
IP66
Other bus systems
MODBUS
EtherNet/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Main circuit
BLDC motors
PM motors
U/f control
Speed control with slip compensation
Sensorless vector control (SLV)
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit