DC1-34018FB-A20CE1 185761 Y7-185761 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 18 A, 7.5 kW..
DC1-34018FB-A20CE1
185761
Y7-185761
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DC1-34018FB-A20CE1 is an Eaton Moeller variable frequency drive utilized in industrial automation to control electric motor speeds and enhance process efficiency. Frequency inverters provide seamless modulation of motor performance, reducing mechanical stress across heavy machinery installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 18 A
- Power consumption (EF000346): 300 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL 508C
Certified by UL for use in Canada
UL report applies to both US and Canada
UL
IEC/EN61800-5
Specification for general requirements: IEC/EN 61800-2
UL File No.: E172143
CSA-C22.2 No. 14
IEC/EN 61800-3
RoHS, ISO 9001
UL Category Control No.: NMMS, NMMS7
RCM
CE
CUL
EAC
Safety requirements: IEC/EN 61800-5-1
UkrSEPRO
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
7-digital display assembly
IGBT inverter
Radio interference suppression filter
PC connection
Control unit
Internal DC link
Breaking resistance
Additional PCB protection
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
Modbus RTU, built in
OP-Bus (RS485), built in
CANopen®, built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
MODBUS
CAN
EtherNet/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Main circuit
Sensorless vector control (SLV)
Speed control with slip compensation
BLDC motors
PM motors
Synchronous reluctance motors
400 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit