View larger
DC1-327D0FB-A20CE1 185836 Y7-185836 EATON ELECTRIC Variable frequency drive, 230 V AC, 3-phase, 7 A, 1.5 kW,..
DC1-327D0FB-A20CE1
185836
Y7-185836
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable frequency drive functions as an electronic motor controller that adjusts operational speeds by converting fixed input frequencies into variable outputs. Such drives are standard components in mechanical engineering installations for improving process accuracy and reducing mechanical wear on machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 7 A
- Power consumption (EF000346): 61.5 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL
UL File No.: E172143
Certified by UL for use in Canada
UL report applies to both US and Canada
CE
EAC
CUL
RoHS, ISO 9001
Specification for general requirements: IEC/EN 61800-2
Safety requirements: IEC/EN 61800-5-1
CSA-C22.2 No. 14
UL Category Control No.: NMMS, NMMS7
RCM
UL 508C
IEC/EN61800-5
IEC/EN 61800-3
IEC/EN61800-3
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
IGBT inverter
Brake chopper
Control unit
Internal DC link
PC connection
Breaking resistance
Radio interference suppression filter
Additional PCB protection
General
150 m, unscreened, maximum permissible, Motor feeder
C3 ≤ 25 m, Radio interference level, maximum motor cable length
200 m, screened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
Modbus RTU, built in
CANopen®, built in
OP-Bus (RS485), built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
Other bus systems
CAN
EtherNet/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
Sensorless vector control (SLV)
Speed control with slip compensation
BLDC motors
PM motors
Synchronous reluctance motors
240 V AC, 3-phase
230 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 30 % MN, Standard - Main circuit