View larger
DC1-32046FB-A20CE1 185776 Y7-185776 EATON ELECTRIC Variable frequency drive, 230 V AC, 3-phase, 46 A, 11 kW,..
DC1-32046FB-A20CE1
185776
Y7-185776
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed to control three-phase AC motors, this Eaton Moeller variable frequency drive (DC1-32046FB-A20CE1) dynamically modifies output voltage and frequency for precise motor speed regulation and energy savings. Such drives are standard in heavy-duty mechanical applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 46 A
- Power consumption (EF000346): 446 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
UL File No.: E172143
Specification for general requirements: IEC/EN 61800-2
UkrSEPRO
CUL
CSA-C22.2 No. 14
EAC
IEC/EN 61800-3
IEC/EN61800-3
RCM
UL 508C
UL report applies to both US and Canada
Certified by UL for use in Canada
IEC/EN61800-5
Safety requirements: IEC/EN 61800-5-1
RoHS, ISO 9001
UL Category Control No.: NMMS, NMMS7
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
Brake chopper
IGBT inverter
Radio interference suppression filter
Internal DC link
Breaking resistance
7-digital display assembly
PC connection
Additional PCB protection
General
C3 ≤ 25 m, Radio interference level, maximum motor cable length
200 m, screened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
150 m, unscreened, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
OP-Bus (RS485), built in
SmartWire-DT, optional
Modbus RTU, built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
Other bus systems
EtherNet/IP
CAN
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Main circuit
Sensorless vector control (SLV)
Speed control with slip compensation
BLDC motors
PM motors
Synchronous reluctance motors
230 V AC, 3-phase
240 V AC, 3-phase