Eaton Electric DC1-32030FB-A6SOE1 operates as a compact general-purpose frequency inverter built to regulate the speed of asynchronous electric motors. Typical applications include managing fans, pumps, and conveyors where reliable speed variation and straightforward parameterization are required to optimize plant efficiency.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 200 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 250 V
- Nominal output current I2N: 30 A
- Power consumption: 304 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 1
- Number of analogue inputs: 2
- Number of digital outputs: 1
- Number of digital inputs: 4
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
IEC/EN 61800-2
Certified by UL for use in Canada
CUL
IEC/EN61800-5
UL File No.: E172143
UL
UL 508C
RoHS, ISO 9001
UkrSEPRO
RCM
EAC
UL report applies to both US and Canada
CE marking
CE
CSA-C22.2 No. 14
IEC/EN 61800-5-1
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3
Features & Functions
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Internal DC link
Brake chopper
Additional PCB protection
Local controls
UV resistance
7-digital display assembly
Radio interference suppression filter
Control unit
Breaking resistance
IGBT inverter
General
C2 ≤ 5 m, maximum motor cable length
100 m, screened, maximum permissible cable length
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
CANopen®, built in
Modbus RTU, built in
OP-Bus (RS485), built in
NEMA 4X
EtherNet/IP
Other bus systems
MODBUS
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Main circuit
Sensorless vector control (SLV)
Synchronous reluctance motors
Speed control with slip compensation
BLDC motors
U/f control
230 V AC, 3-phase
240 V AC, 3-phase