View larger
DC1-32030FB-A66OE1 199425 Y7-199425 EATON ELECTRIC DC1-32030FB-A66OE1
DC1-32030FB-A66OE1
199425
Y7-199425
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Part DC1-32030FB-A66OE1 from Eaton Moeller is a robust variable frequency drive built to govern the operational speed of three-phase electric motors. Facilities across many industries rely on this component category to improve energy efficiency, enhance process accuracy, and safeguard mechanical drives from sudden voltage spikes.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 30 A
- Power consumption (EF000346): 304 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-5-1
CE marking
IEC/EN61800-5
UL File No.: E172143
UL 508C
CUL
UkrSEPRO
UL Listed
CSA-C22.2 No. 14
IEC/EN 61800-2
IEC/EN 61800-3
UL report applies to both US and Canada
Certified by UL for use in Canada
RoHS, ISO 9001
CE
UL
RCM
UL Category Control No.: NMMS, NMMS7
Features & Functions
Parameterization: Keypad
Parameterization: Fieldbus
Parameterization: drivesConnect
Brake chopper
7-digital display assembly
Additional PCB protection
Breaking resistance
Control unit
Internal DC link
PC connection
UV resistance
Radio interference suppression filter
General
100 m, screened, maximum permissible cable length
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C3 ≤ 25 m, maximum motor cable length
150 m, unscreened, maximum permissible cable length
200 m, screened, with motor choke, maximum permissible cable length
OP-Bus (RS485), built in
CANopen®, built in
Modbus RTU, built in
NEMA 4X
MODBUS
EtherNet/IP
CAN
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 4000 m
Main circuit
BLDC motors
PM motors
Sensorless vector control (SLV)
Synchronous reluctance motors
U/f control
230 V AC, 3-phase
240 V AC, 3-phase