View larger
DC1-32011NB-A20CE1 185830 Y7-185830 EATON ELECTRIC Variable frequency drive, 230 V AC, 3-phase, 10.5 A, 2.2 ..
DC1-32011NB-A20CE1
185830
Y7-185830
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DC1-32011NB-A20CE1 185830 Y7-185830 EATON ELECTRIC Variable frequency drive functions as an essential electronic controller that adjusts the operating speed of standard asynchronous motors. These devices are widely integrated into factory production lines to achieve smooth motion profiles and improve system efficiency.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 10.5 A
- Power consumption (EF000346): 90.2 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL report applies to both US and Canada
UkrSEPRO
UL 508C
CSA-C22.2 No. 14
IEC/EN61800-3
CUL
EAC
IEC/EN61800-5
Safety requirements: IEC/EN 61800-5-1
UL Category Control No.: NMMS, NMMS7
Certified by UL for use in Canada
RoHS, ISO 9001
IEC/EN 61800-3
RCM
UL
CE
Specification for general requirements: IEC/EN 61800-2
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
IGBT inverter
PC connection
Control unit
7-digital display assembly
Breaking resistance
Internal DC link
Additional PCB protection
General
150 m, unscreened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
OP-Bus (RS485), built in
SmartWire-DT, optional
CANopen®, built in
In conjunction with DX-NET-SWD3 SmartWire DT module
NEMA Other
EtherNet/IP
MODBUS
Other bus systems
Climatic environmental conditions
Max. 4000 m
Main circuit
Sensorless vector control (SLV)
Speed control with slip compensation
BLDC motors
PM motors
Synchronous reluctance motors
240 V AC, 3-phase
240 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit