EATON - MOELLER DC1-1D4D3NN-A6SOE1 DC1-1D4D3NN-A6SOE1 199396 Y7-199396 EATON ELECTRIC DC1-1D4D3NN-A6SOE1 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DC1-1D4D3NN-A6SOE1 199396 Y7-199396 EATON ELECTRIC DC1-1D4D3NN-A6SOE1

DC1-1D4D3NN-A6SOE1

199396

Y7-199396

EATON - MOELLER

1 Pcs.

DC1-1D4D3NN-A6SOE1 Eaton DC1 Variable frequency drive, 115 V AC, single-phase, 4.3 A, 0.75 kW, IP66/NEMA 4X, 7-digital display assembly, Local controls, Additional PCB protection, UV resistant, FS1 Variable frequency drive, Part group reference (e.g. DIL): DC1, Rated operational voltage: Ue = 115 V AC, single-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 110 (-10%) - 115 (+10%) V, Rated operational current At 150% overload: Ie = 4.3 A, Note: Rated operational current at an operating frequency of 6 kHz and an ambient air temperature of +40 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For normal internally and externally ventilated four-pole three-phase asynchronous motors with 1500 rpm at 50 Hz and 1800 rpm at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V , 50 Hz, Assigned motor rating 150 % Overload: P = 0.75 kW, 150 % Overload: IM = 3.2 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 1 HP, Assigned motor rating 150 % Overload: IM = 4.2 A, Degree of Protection: IP66/NEMA 4X, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): SmartWire-DT, Fitted with: 7-digital display assembly, Local controls, Additional PCB protection, UV resistant, Frame size: FS1, Standards: General requirements: IEC/EN 61800-2, EMV requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Automation > Frequency converter less than 1 kV
Power XL Frequency Converters

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller variable frequency drive regulates motor speed by converting single-phase incoming power into a controlled three-phase output. These compact units are frequently utilized in smaller machinery setups to provide smooth acceleration, adjustable operating speeds, and reliable overload protection.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Mains voltage (EF006780): 110 V
  • Mains frequency (EF006783): 50/60 Hz
  • Number of phases input (EF007117): 1
  • Number of phases output (EF006998): 3
  • Max. output frequency (EF007350): 500 Hz
  • Max. output voltage (EF009560): 250 V
  • Nominal output current I2N (EF009561): 4.3 A
  • Power consumption (EF000346): 37.5 W
  • Relative symmetric net frequency tolerance (EF007454): 10 %
  • Relative symmetric net voltage tolerance (EF007453): 10 %
  • Number of analogue outputs (EF001995): 1
  • Number of analogue inputs (EF001994): 2
  • Number of digital outputs (EF001993): 1
  • Number of digital inputs (EF001992): 4
  • With control element (EF001538): Yes
  • Application in industrial area permitted (EF007294): Yes

More info

▲

General specifications

Product Name
Eaton DC1 Variable frequency drive
Catalog Number
199396
Model Code
DC1-1D4D3NN-A6SOE1
EAN
4015081977857
Product Length/Depth
162 mm
Product Height
232 mm
Product Width
161 mm
Product Weight
2.5 kg
Certifications
RoHS, ISO 9001
CE
IEC/EN 61800-5-1
UL Category Control No.: NMMS, NMMS7
UL File No.: E172143
UL Listed
CSA-C22.2 No. 14
CUL
RCM
EAC
UL 508C
Certified by UL for use in Canada
UL
UkrSEPRO
IEC/EN61800-5
UL report applies to both US and Canada
CE marking
IEC/EN 61800-2
IEC/EN 61800-3

Features & Functions

Features
Parameterization: drivesConnect mobile (App)
Parameterization: drivesConnect
Parameterization: Fieldbus
Parameterization: Keypad
Fitted with:
Additional PCB protection
UV resistance
PC connection
7-digital display assembly
IGBT inverter
Control unit
Local controls
Internal DC link

General

Cable length
150 m, unscreened, with motor choke, maximum permissible, Motor feeder
50 m, screened, maximum permissible, Motor feeder
75 m, unscreened, maximum permissible, Motor feeder
100 m, screened, with motor choke, maximum permissible, Motor feeder
Communication interface
Modbus RTU, built in
OP-Bus (RS485), built in
CANopen®, built in
SmartWire-DT, optional
Connection to SmartWire-DT
No
Degree of protection
IP66
NEMA 4X
Frame size
FS1
Mounting position
Vertical
Product category
Variable frequency drives
Protection
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
Protocol
MODBUS
EtherNet/IP
CAN
Other bus systems
Radio interference class
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Suitable for
Branch circuits, (UL/CSA)

Climatic environmental conditions

Altitude
Above 1000 m with 1 % derating per 100 m
Max. 4000 m
Ambient operating temperature - min
-20 °C
Ambient operating temperature - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
60 °C
Climatic proofing
< 95 average relative humidity (RH), no condensation, no corrosion

Main circuit

Efficiency
97 % (η)
Input current ILN at 150% overload
15.8 A
Leakage current at ground IPE - max
4.8 mA
Mains switch-on frequency
Maximum of one time every 30 seconds
Mains voltage - min
110 V
Mains voltage - max
115 V
Operating mode
Sensorless vector control (SLV)
Speed control with slip compensation
BLDC motors
PM motors
U/f control
Synchronous reluctance motors
Output frequency - min
0 Hz
Output frequency - max
500 Hz
Output voltage (U2)
230 V AC, 3-phase
Overload current IL at 150% overload
6.45 A
Rated control supply voltage
10 V DC (Us, max. 10 mA)
Rated frequency - min
48 Hz
Rated frequency - max
62 Hz
Rated operational current (Ie)
4.3 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
Rated operational voltage
115 V AC, 1-phase
Resolution
0.1 Hz (Frequency resolution, setpoint value)
Short-circuit protection rating
25 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
Starting current - max
175 % IH
Supply frequency
50/60 Hz
Switching frequency
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
System configuration type
AC supply systems with earthed center point
Voltage rating - max
120 V

Motor rating

Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload
4.2 A
Assigned motor current IM at 230 V, 50 Hz, 150% overload
3.2 A
Assigned motor power at 230/240 V, 60 Hz, 1-phase
1 HP

Braking function

Braking torque
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit

Control circuit

Number of inputs (analog)
2
Number of inputs (digital)
4
Number of outputs (analog)
1
Number of outputs (digital)
1
Number of relay outputs
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))