View larger
DC1-1D4D3NN-A6SOE1 199396 Y7-199396 EATON ELECTRIC DC1-1D4D3NN-A6SOE1
DC1-1D4D3NN-A6SOE1
199396
Y7-199396
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable frequency drive regulates motor speed by converting single-phase incoming power into a controlled three-phase output. These compact units are frequently utilized in smaller machinery setups to provide smooth acceleration, adjustable operating speeds, and reliable overload protection.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 110 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 37.5 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CE
IEC/EN 61800-5-1
UL Category Control No.: NMMS, NMMS7
UL File No.: E172143
UL Listed
CSA-C22.2 No. 14
CUL
RCM
EAC
UL 508C
Certified by UL for use in Canada
UL
UkrSEPRO
IEC/EN61800-5
UL report applies to both US and Canada
CE marking
IEC/EN 61800-2
IEC/EN 61800-3
Features & Functions
Parameterization: drivesConnect
Parameterization: Fieldbus
Parameterization: Keypad
UV resistance
PC connection
7-digital display assembly
IGBT inverter
Control unit
Local controls
Internal DC link
General
50 m, screened, maximum permissible, Motor feeder
75 m, unscreened, maximum permissible, Motor feeder
100 m, screened, with motor choke, maximum permissible, Motor feeder
OP-Bus (RS485), built in
CANopen®, built in
SmartWire-DT, optional
NEMA 4X
EtherNet/IP
CAN
Other bus systems
Climatic environmental conditions
Max. 4000 m
Main circuit
Speed control with slip compensation
BLDC motors
PM motors
U/f control
Synchronous reluctance motors
Motor rating
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit