An Eaton Moeller variable frequency drive delivers versatile motor speed control across manufacturing plants, optimizing fluid dynamics and conveyor throughput. By adjusting voltage and frequency parameters dynamically, these units reduce energy consumption and protect mechanical components from excessive wear. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.1 A
- Power consumption (EF000346): 53 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL report applies to both US and Canada
IEC/EN61800-3
UL
UL File No.: E172143
IEC/EN61800-5
RCM
CSA
CUL
IEC/EN 61800-2
Certified by UL for use in Canada
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3
CSA-C22.2 No. 14
RoHS, ISO 9001
Safety: EN 61800-5-1: 2003
UL 508C
CSA-C22.2 No. 274
IEC/EN 61800-5-1
CE marking
Features & Functions
Parameterization: Keypad
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
PC connection
IGBT inverter
Radio interference suppression filter
Additional PCB protection
General
C3 ≤ 10 m, maximum motor cable length
C1 ≤ 1 m, maximum motor cable length
10 m, screened, maximum permissible cable length
Modbus RTU
OP-Bus (RS485)
NEMA Other
MODBUS
Other bus systems
C1: for conducted emissions only
Ambient conditions, mechanical
Depending on the cooling
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
Speed control with slip compensation
BLDC motors
PM motors
Sensorless vector control (SLV)
Synchronous reluctance motors
480 V AC, 3-phase