View larger
DB1-344D1FB-N2CC 197564 EATON ELECTRIC Cool Plate Frequency Converter Ent: 3 x 400 V Salt: 3 x 400 V 4.1 A 1..
DB1-344D1FB-N2CC
197564
EATON - MOELLER
10 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DB1-344D1FB-N2CC 197564 EATON ELECTRIC Cool Plate Frequency Converter Ent: 3 x 400 V Salt: 3 x 400 V 4.1 A 1.. is a cool plate frequency converter utilized to regulate the rotational speed and torque of AC motors by varying the supplied electrical frequency and voltage. These electronic power units are widely integrated into industrial motor circuits to optimize energy efficiency and process control. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.1 A
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
- Supporting protocol for TCP/IP (EF003050): No
More info
▲General specifications
IEC/EN 61800-2
IEC/EN61800-5
UL Category Control No.: NMMS, NMMS7
CE
UL report applies to both US and Canada
IEC/EN 61800-3
UL
RCM
CSA-C22.2 No. 14
CUL
RoHS, ISO 9001
UL File No.: E172143
UL 508C
Certified by UL for use in Canada
Safety: EN 61800-5-1: 2003
Features & Functions
Internal DC link
Radio interference suppression filter
Breaking resistance
PC connection
General
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 10 m, maximum motor cable length
OP-Bus (RS485)
CANopen®
NEMA Other
MODBUS
Other bus systems
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Ambient conditions, mechanical
As required
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 2000 m
Main circuit
Speed control with slip compensation
480 V AC, 3-phase
480 V AC, 3-phase