View larger
DB1-342D2FN-N2CC 197196 Y7-197196 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 2.2 A, 0.75 kW..
DB1-342D2FN-N2CC
197196
Y7-197196
EATON - MOELLER
10 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller manufactured the DB1-342D2FN-N2CC variable frequency drive to provide precise motor control within automated electrical networks. These devices adjust the frequency and voltage supplied to electric motors, allowing for seamless speed adjustments and energy savings across production lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.2 A
- Power consumption (EF000346): 27 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CUL
UL File No.: E172143
IEC/EN 61800-3
UL 508C
UL Category Control No.: NMMS, NMMS7
RCM
Safety: EN 61800-5-1: 2003
UL report applies to both US and Canada
CSA-C22.2 No. 14
IEC/EN61800-3
Certified by UL for use in Canada
IEC/EN61800-5
CE
CSA
UL
RoHS, ISO 9001
CSA-C22.2 No. 274
IEC/EN 61800-5-1
CE marking
Features & Functions
Parameterization: drivesConnect mobile (App)
Parameterization: Fieldbus
Parameterization: Keypad
PC connection
Internal DC link
IGBT inverter
Additional PCB protection
General
C1 ≤ 1 m, maximum motor cable length
C3 ≤ 10 m, maximum motor cable length
C2 ≤ 3 m, maximum motor cable length
OP-Bus (RS485)
CANopen®
NEMA Other
Other bus systems
CAN
Ambient conditions, mechanical
As required
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
U/f control
480 V AC, 3-phase
400 V AC, 3-phase