Variable frequency drive, 230 V AC, 1-phase, 7 A, 1.5 kW, IP20/NEMA0, Radio interference suppression filter, Additional PCB protection, PFC (Power Factor Compensation), FS1C FU DB1 CP 1~/3~230 V 7A 1.5kW EMC PFC

Automation > Frequency converter less than 1 kV
Power XL Frequency Converters

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Variable frequency drive, 230 V AC, 1-phase, 7 A, 1.5 kW, IP20/NEMA0, Radio interference suppression filter, Additional PCB protection, PFC (Power Factor Compensation), FS1C
Variable frequency drive DB1, Rated operational voltage: Ue = 230 V AC, 1-phase, 240 V AC, single-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, 240 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, Rated operational current At 150% overload: Ie = 7 A, Note: Rated operational current at an operating frequency of 8 kHz and an ambient air temperature of +60°C, depending on cooling, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For normal internally and externally ventilated four-pole three-phase asynchronous motors with 1500 rpm at 50 Hz and 1800 rpm at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 1.5 kW, 150 % Overload: IM = 7 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 2 HP, Assigned motor rating 150 % Overload: IM = 7 A, Degree of Protection: IP20/NEMA0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fitted with: Radio interference suppression filter, Additional PCB protection, PFC (Power Factor Compensation), Frame size: FS1C, Standards: General requirements: IEC/EN 61800-2, EMV requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Delivery program

Photo
DB1-1M4D3FN-N2CC-PFC_CDB1-1M4D3FN-N2CC-PFC_R
Product range
Variable frequency drives
Part group reference (e.g. DIL)
DB1
0000SPC-706
Rated operational voltage [Ue]
230 V AC, 1-phase
240 V AC, single-phase
Output voltage with Ve[U2]
230 V AC, 3-phase
240 V AC, 3-phase
Mains voltage (50/60Hz) [ULN]
200 (-10%) - 240 (+10%) V
Rated operational current [Ie]
At 150% overload [Ie]
7 A
Note
Rated operational current at an operating frequency of 8 kHz and an ambient air temperature of +60°C
depending on cooling
Assigned motor rating
Note
For normal internally and externally ventilated four-pole three-phase asynchronous motors with 1500 rpm at 50 Hz and 1800 rpm at 60 Hz
Note
Overload cycle for 60 s every 600 s
Note
at 230 V, 50 Hz
150 % Overload [P]
1.5 kW
150 % Overload [IM]
7 A
Note
at 220 - 240 V, 60 Hz
150 % Overload [P]
2 HP
150 % Overload [IM]
7 A
Degree of Protection
IP20/NEMA0
Interface/field bus (built-in)
OP-Bus (RS485)/Modbus RTU, CANopen®
Fitted with
Radio interference suppression filter
Additional PCB protection
PFC (Power Factor Compensation)
Frame size
FS1C
Connection to SmartWire-DT
no

Technical data

General
Standards
General requirements: IEC/EN 61800-2
EMV requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5-1
Production quality
RoHS, ISO 9001
Climatic proofing [ρw]
< 95%, average relative humidity (RH), non-condensing, non-corrosive %
Ambient temperatureOperating ambient temperature min.
-10 °C
Ambient temperatureOperating ambient temperature max.
+50 °C
Ambient temperature
operation (with 150 % overload)
Ambient temperatureStorage [ϑ]
-40 - +60 °C
Radio interference levelRadio interference class (EMC)
C1 (for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Radio interference levelmaximum motor cable length [I]
C1 ≤ 1 m
C2 ≤ 3 m
C3 ≤ 10 m m
Mechanical shock resistance
15 (11 m/s, EN 60068-2-27) g
Mounting position
As required
depending on the cooling
Altitude
0 - 1000 m above sea level
Above 1000 m: 1% derating for every 100 m
max. 2000 m m
Degree of Protection
IP20/NEMA0
Protection against direct contact
BGV A3 (VBG4, finger- and back-of-hand proof)
Main circuit
SupplyRated operational voltage [Ue]
230 V AC, 1-phase
240 V AC, single-phase
SupplyMains voltage (50/60Hz) [ULN]
200 (-10%) - 240 (+10%) V
SupplyInput current (150% overload) [ILN]
8.7 A
SupplySystem configuration
AC supply systems with earthed center point
SupplySupply frequency [fLN]
50/60 Hz
SupplyFrequency range [fLN]
48 - 62 Hz
SupplyMains switch-on frequency
Maximum of one time every 30 seconds
Power sectionFunction
Variable frequency drive with internal DC link and IGBT inverter
Power sectionOverload current (150% overload) [IL]
10.5 A
Power sectionmax. starting current (High Overload) [IH]
175 %
Power sectionNote about max. starting current
for 3.75 seconds every 600 seconds
Power sectionOutput voltage with Ve[U2]
230 V AC, 3-phase
240 V AC, 3-phase
Power sectionOutput Frequency [f2]
0 - 50/60 (max. 500) Hz
Power sectionOperation Mode
U/f control
Speed control with slip compensation
sensorless vector control (SLV)
PM motors
Synchronous reluctance motors
BLDC motors
Power sectionFrequency resolution (setpoint value) [Δf]
0.1 Hz
Power sectionRated operational currentAt 150% overload [Ie]
7 A
Power sectionNote
Rated operational current at an operating frequency of 8 kHz and an ambient air temperature of +60°C
depending on cooling
Power sectionHeat dissipation at current/speed [%]Current = 100%Speed = 0 % [PV]
55 W
Power sectionHeat dissipation at current/speed [%]Current = 100%Speed = 50 % [PV]
80 W
Power sectionHeat dissipation at current/speed [%]Current = 100%Speed = 90 % [PV]
105 W
Power sectionHeat dissipation at current/speed [%]Current = 50 %Speed = 0 % [PV]
41 W
Power sectionHeat dissipation at current/speed [%]Current = 50 %Speed = 50 % [PV]
52 W
Power sectionHeat dissipation at current/speed [%]Current = 50 %Speed = 90 % [PV]
63 W
Power sectionHeat dissipation at current/speed [%]Current = 50 %Speed = 0 % [PV]
33 W
Power sectionHeat dissipation at current/speed [%]Current = 50 %Speed = 50 % [PV]
39 W
Power sectionMaximum leakage current to ground (PE) without motor [IPE]
3.5 (230 V) mA
Power sectionFitted with
Radio interference suppression filter
Additional PCB protection
PFC (Power Factor Compensation)
Power sectionFrame size
FS1C
Motor feederNote
For normal internally and externally ventilated four-pole three-phase asynchronous motors with 1500 rpm at 50 Hz and 1800 rpm at 60 Hz
Motor feederNote
Overload cycle for 60 s every 600 s
Motor feederNote
at 230 V, 50 Hz
Motor feeder150 % Overload [P]
1.5 kW
Motor feederNote
at 220 - 240 V, 60 Hz
Motor feeder150 % Overload [P]
2 HP
Motor feedermaximum permissible cable length [I]
screened: 10 m
Motor feederApparent powerApparent power at rated operation 230 V [S]
1.61 kVA
Motor feederApparent powerApparent power at rated operation 240 V [S]
1.68 kVA
Motor feederBraking functionStandard braking torque
max. 30 % MN
Motor feederBraking functionDC braking torque
Max. 100% of rated operational current Ie, variable
Control section
Reference voltage [Us]
10 V DC (max. 10 mA) V
Analog inputs
2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA
Analog outputs
1, parameterizable, 0 - 10 V
Digital inputs
4, parameterizable, max. 30 V DC
Digital outputs
1, parameterizable, 24 V DC
Relay outputs
1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)
Interface/field bus (built-in)
OP-Bus (RS485)/Modbus RTU, CANopen®
Expansion slots
1
Assigned switching and protective elements
Power WiringSafety device (fuse or miniature circuit-breaker)IEC (Type B, gG), 150 %
FAZ-B16/1N
Power WiringSafety device (fuse or miniature circuit-breaker)UL (Class CC or J)
15 A
Power WiringMains contactor150 % overload (CT/IH, at 50 °C)
DILM7-… + DILM12-XP1
Power WiringMain choke150 % overload (CT/IH, at 50 °C)
DX-LN1-013
Power WiringRadio interference suppression filter (external, 150 %)
DX-EMC12-014-FS1
Motor feedermotor choke150 % overload (CT/IH, at 50 °C)
DX-LM3-008
Motor feederSine filter150 % overload (CT/IH, at 50 °C)
DX-SIN3-010

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-10 °C
Operating ambient temperature max.
+50 °C

Technical data ETIM 8.0

Low-voltage industrial components (EG000017) / Frequency converter =< 1 kV (EC001857)
Electric engineering, automation, process control engineering / Electrical drive / Static frequency converter / Static frequency converter = < 1 kV ([email protected] [AKE177014])
Mains voltage
200 - 240 V
Mains frequency
50/60 Hz
Number of phases input
1
Number of phases output
3
Max. output frequency
500 Hz
Max. output voltage
250 V
Nominal output current I2N
7 A
Max. output at quadratic load at rated output voltage
0.75 kW
Max. output at linear load at rated output voltage
0.75 kW
Relative symmetric net frequency tolerance
10 %
Relative symmetric net voltage tolerance
10 %
Number of analogue outputs
1
Number of analogue inputs
2
Number of digital outputs
1
Number of digital inputs
4
With control element
No
Application in industrial area permitted
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
No
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Height
186 mm
Width
128 mm
Depth
81 mm

Approvals

Product Standards
UL 508C; CSA-C22.2 No. 274; IEC/EN 61000-3-2; IEC/EN61800-2; IEC/EN61800-3; IEC/EN61800-5-1; CE marking
UL File No.
E172143
UL Category Control No.
NMMS2, NMMS8
CSA File No.
UL report applies to both US and Canada
North America Certification
UL listed, certified by UL for use in Canada
Specially designed for North America
No
Suitable for
Branch circuits
Max. Voltage Rating
1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey)
Degree of Protection
IEC: IP20, NEMA 0

Dimensions

8230DIM-173

ETIM for 199739 Low-voltage industrial controls and switchgear (EC001857)
Feature Name Feature Value
Mains voltage (EF006780) 200 V
Mains frequency (EF006783) 50/60 Hz
Number of phases input (EF007117) 1
Number of phases output (EF006998) 3
Max. output frequency (EF007350) 500 Hz
Max. output voltage (EF009560) 250 V
Nominal output current I2N (EF009561) 7 A
Max. output at quadratic load at rated output voltage (EF007366) 0.75 kW
Max. output at linear load at rated output voltage (EF007364) 0.75 kW
Power consumption (EF000346) 105 W
Relative symmetric net frequency tolerance (EF007454) 10 %
Relative symmetric net voltage tolerance (EF007453) 10 %
Number of analogue outputs (EF001995) 1
Number of analogue inputs (EF001994) 2
Number of digital outputs (EF001993) 1
Number of digital inputs (EF001992) 4
With control element (EF001538) No
Application in industrial area permitted (EF007294) Yes
Application in domestic- and commercial area permitted (EF007295) Yes
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) Yes
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) Yes
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for BACnet (EF011944) No
Supporting protocol for other bus systems (EF003062) Yes
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 1
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) No
With PC connection (EF006107) Yes
Integrated breaking resistance (EF007293) No
4-quadrant operation possible (EF006803) No
Type of converter (EF006978) U converter
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other
Height (EF000040) 185.98 mm
Width (EF000008) 127.98 mm
Depth (EF000049) 90 mm