View larger
DB1-124D3FN-N2CC 197194 Y7-197194 EATON ELECTRIC Variable frequency drive, 230 V AC, 1-phase, 4.3 A, 0.75 kW..
DB1-124D3FN-N2CC
197194
Y7-197194
EATON - MOELLER
10 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DB1-124D3FN-N2CC variable frequency drive acts as an adjustable motor controller to optimize energy consumption and speed in automated tasks. These robust electronic converters are deployed across production lines to provide seamless acceleration, deceleration, and frequency modulation for AC machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 4.3 A
- Power consumption (EF000346): 60 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 4
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
RoHS, ISO 9001
RCM
UL
IEC/EN 61800-2
UL File No.: E172143
Safety: EN 61800-5-1: 2003
UL 508C
CUL
Certified by UL for use in Canada
IEC/EN 61800-3
CSA-C22.2 No. 14
UL report applies to both US and Canada
CE
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-5
CSA-C22.2 No. 274
IEC/EN 61800-5-1
CE marking
Features & Functions
Parameterization: Keypad
Parameterization: drivesConnect
Parameterization: drivesConnect mobile (App)
IGBT inverter
Internal DC link
Radio interference suppression filter
Additional PCB protection
General
C3 ≤ 10 m, maximum motor cable length
10 m, screened, maximum permissible cable length
C1 ≤ 1 m, maximum motor cable length
CANopen®
OP-Bus (RS485)
NEMA Other
CAN
Other bus systems
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Ambient conditions, mechanical
As required
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 2000 m
Main circuit
Speed control with slip compensation
BLDC motors
PM motors
Sensorless vector control (SLV)
Synchronous reluctance motors
240 V AC, 3-phase
240 V AC, 1-phase