DA1-359D0NB-B66C 176988 Y7-176988 EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 9 A, 5.5 kW, I..
DA1-359D0NB-B66C
176988
Y7-176988
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller DA1-359D0NB-B66C variable frequency drive delivers robust motor control capabilities designed for demanding industrial environments. Engineers incorporate these units to handle complex motion profiles, improve energy efficiency, and protect electrical assets across diverse production lines.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 500 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 9 A
- Power consumption (EF000346): 165 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Safety: EN 61800-5-1: 2003
UL 508C
UL
EAC
IEC/EN61800-5
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3
UkrSEPRO
CSA-C22.2 No. 14
Certified by UL for use in Canada
CUL
CE
Specification for general requirements: IEC/EN 61800-2
UL File No.: E172143
UL report applies to both US and Canada
IEC/EN61800-3
RoHS, ISO 9001
General
100 m, screened, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
EtherCAT, optional
OP-Bus (RS485), built in
Modbus-TCP, optional
PROFIBUS, optional
DeviceNet, optional
Modbus RTU, built in
Ethernet IP, optional
PROFINET, optional
IP66
Control unit
PC connection
Brake chopper
Internal DC link
Additional PCB protection
OLED display
Breaking resistance
DeviceNet
CAN
Other bus systems
PROFIBUS
MODBUS
EtherNet/IP
TCP/IP
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 1000 m
Main circuit
134 W at 100% current and 50% speed
153 W at 100% current and 90% speed
76 W at 25% current and 0% speed
76 W at 25% current and 50% speed
77 W at 50% current and 0% speed
94 W at 50% current and 90% speed
95 W at 50% current and 50% speed
Optional: Vector control with feedback (CLV)
U/f control
Speed control with slip compensation
500 V AC, 3-phase
600 V AC, 3-phase
NH fuse used together with TB00-D fuse base, Power wiring, Assigned switching and protective elements
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit