View larger
DA1-35065NB-B55C 176970 Y7-176970 EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 65 A, 45 kW, I..
DA1-35065NB-B55C
176970
Y7-176970
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller variable frequency drive DA1-35065NB-B55C (176970) serves as a heavy-duty inverter engineered to regulate speed and torque profiles for demanding three-phase motor applications. Industrial systems rely on such robust controllers to achieve smooth operational cycles and high energy efficiency under heavy loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 500 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 65 A
- Power consumption (EF000346): 1350 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-5
RoHS, ISO 9001
UL
CE
CSA-C22.2 No. 14
Specification for general requirements: IEC/EN 61800-2
EAC
UL 508C
DNV
Safety: EN 61800-5-1: 2003
UkrSEPRO
UL Category Control No.: NMMS, NMMS7
RCM
UL report applies to both US and Canada
IEC/EN61800-3
CUL
UL File No.: E172143
IEC/EN 61800-3
General
100 m, screened, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
EtherCAT, optional
CANopen®, built in
DeviceNet, optional
PROFIBUS, optional
Modbus RTU, built in
Ethernet IP, optional
PROFINET, optional
OP-Bus (RS485), built in
Modbus-TCP, optional
In conjunction with DX-NET-SWD1 SmartWire DT module
IP55
Additional PCB protection
Internal DC link
Brake chopper
IGBT inverter
DC link choke
PC connection
Breaking resistance
Control unit
CAN
PROFIBUS
MODBUS
PROFINET IO
Other bus systems
DeviceNet
TCP/IP
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
328 W at 25% current and 0% speed
328 W at 25% current and 50% speed
328 W at 50% current and 0% speed
370 W at 50% current and 50% speed
420 W at 50% current and 90% speed
649 W at 100% current and 0% speed
836 W at 100% current and 50% speed
U/f control
Speed control with slip compensation
Sensorless vector control (SLV)
600 V AC, 3-phase
600 V AC, 3-phase
NH fuse used together with TB00-D fuse base, Power wiring, Assigned switching and protective elements
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit