Eaton Moeller DA1-35054NB-B20C is a frequency inverter designed to regulate motor speed and torque in demanding industrial automation architectures. Units of this type provide precise control over AC motors to optimize throughput, reduce mechanical wear, and improve energy efficiency across diverse manufacturing workflows. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 500 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 54 A
- Power consumption (EF000346): 1110 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Safety: EN 61800-5-1: 2003
EAC
UL
Certified by UL for use in Canada
UL File No.: E172143
RCM
RoHS, ISO 9001
IEC/EN 61800-3
IEC/EN61800-3
IEC/EN 61800-2
UkrSEPRO
CE
CUL
UL report applies to both US and Canada
UL Category Control No.: NMMS, NMMS7
UL 508C
General
100 m, screened, maximum permissible cable length
200 m, screened, with motor choke, maximum permissible cable length
200 m, unscreened, with motor choke, maximum permissible cable length
Modbus RTU
EtherCAT, optional
OP-Bus (RS485)
Modbus-TCP, optional
Ethernet IP, optional
SmartWire-DT, optional
DeviceNet, optional
PROFIBUS, optional
PROFINET, optional
In conjunction with DX-NET-SWD1 SmartWire DT module
NEMA Other
OLED display
Additional PCB protection
IGBT inverter
Brake chopper
DC link choke
Control unit
Internal DC link
Breaking resistance
EtherNet/IP
DeviceNet
MODBUS
Other bus systems
TCP/IP
CAN
PROFIBUS
Climatic environmental conditions
Max. 4000 m
Max. 1000 m
Main circuit
310 W at 25% current and 50% speed
350 W at 50% current and 0% speed
410 W at 50% current and 50% speed
590 W at 100% current and 0% speed
630 W at 50% current and 90% speed
640 W at 100% current and 50% speed
810 W at 100% current and 90% speed
Optional: Vector control with feedback (CLV)
Speed control with slip compensation
Sensorless vector control (SLV)
600 V AC, 3-phase
600 V AC, 3-phase
LPJ fuse used together with JM60100-3 fuse base, Power wiring, Assigned switching and protective elements
Motor rating
Apparent power
Braking function
Adjustable to 100 % (DC)
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit