View larger
DA1-35034NB-B55C 176967 Y7-176967 EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 34 A, 22 kW, I..
DA1-35034NB-B55C
176967
Y7-176967
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Electric Variable frequency drive, 500 V AC, 3-phase, 34 A, 22 kW, I.. delivers high-capacity motor control for demanding industrial applications requiring precise torque and speed regulation. Industrial frequency drives improve system longevity by minimizing mechanical wear during motor startup and operation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 500 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 34 A
- Power consumption (EF000346): 660 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CUL
CE
EAC
IEC/EN 61800-3
UL Category Control No.: NMMS, NMMS7
UL report applies to both US and Canada
IEC/EN61800-5
UL 508C
UL File No.: E172143
DNV
Specification for general requirements: IEC/EN 61800-2
Certified by UL for use in Canada
CSA-C22.2 No. 14
UL
IEC/EN61800-3
Safety: EN 61800-5-1: 2003
RCM
UkrSEPRO
General
150 m, unscreened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
PROFINET, optional
OP-Bus (RS485), built in
Modbus RTU, built in
Modbus-TCP, optional
EtherCAT, optional
Ethernet IP, optional
CANopen®, built in
PROFIBUS, optional
SmartWire-DT, optional
Yes
NEMA 12
Additional PCB protection
PC connection
Breaking resistance
Control unit
Internal DC link
IGBT inverter
OLED display
Other bus systems
PROFIBUS
DeviceNet
CAN
EtherNet/IP
PROFINET IO
TCP/IP
Climatic environmental conditions
Max. 1000 m
Max. 4000 m
Main circuit
193 W at 25% current and 50% speed
220 W at 50% current and 0% speed
252 W at 50% current and 50% speed
285 W at 50% current and 90% speed
361 W at 100% current and 0% speed
431 W at 100% current and 50% speed
500 W at 100% current and 90% speed
Optional: Vector control with feedback (CLV)
Speed control with slip compensation
Sensorless vector control (SLV)
600 V AC, 3-phase
600 V AC, 3-phase
LPJ fuse used together with J60060-3 fuse base, Power wiring, Assigned switching and protective elements
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit