View larger
DA1-35034NB-B20C 197500 Y7-197500 EATON ELECTRIC Frequency inverter, 500 V AC, 3-phase, 34 A, 22 kW, IP20/NE..
DA1-35034NB-B20C
197500
Y7-197500
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A frequency inverter functions as an adjustable-speed drive that governs AC motor performance by altering input frequency and voltage parameters. Industrial plants deploy these electronic power units to control conveyor systems, pumps, and fans dynamically, ensuring reduced mechanical wear and higher operational throughput. Pricing, availability and lead time are confirmed per enquiry through an RFQ for part number DA1-35034NB-B20C by Eaton Moeller.
- Mains voltage (EF006780): 500 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 34 A
- Power consumption (EF000346): 660 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
RoHS, ISO 9001
CUL
UL Category Control No.: NMMS, NMMS7
Safety: EN 61800-5-1: 2003
Certified by UL for use in Canada
IEC/EN 61800-2
EAC
UkrSEPRO
UL
UL File No.: E172143
RCM
CE
IEC/EN61800-5
UL report applies to both US and Canada
UL 508C
General
200 m, screened, with motor choke, maximum permissible cable length
200 m, unscreened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
Modbus-TCP, optional
PROFINET, optional
SmartWire-DT, optional
Modbus RTU
Ethernet IP, optional
CANopen®
OP-Bus (RS485)
DeviceNet, optional
PROFIBUS, optional
In conjunction with DX-NET-SWD1 SmartWire DT module
NEMA Other
Internal DC link
Control unit
Additional PCB protection
OLED display
PC connection
IGBT inverter
Brake chopper
MODBUS
EtherNet/IP
PROFIBUS
DeviceNet
TCP/IP
CAN
PROFINET IO
Climatic environmental conditions
Max. 4000 m
Max. 1000 m
Main circuit
192 W at 25% current and 50% speed
223 W at 50% current and 0% speed
249 W at 50% current and 50% speed
278 W at 50% current and 90% speed
360 W at 100% current and 0% speed
417 W at 100% current and 50% speed
499 W at 100% current and 90% speed
Sensorless vector control (SLV)
Speed control with slip compensation
U/f control
600 V AC, 3-phase
500 V AC, 3-phase
LPJ fuse used together with J60060-3 fuse base, Power wiring, Assigned switching and protective elements
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit