View larger
DA1-35012NB-B6SC 177017 Y7-177017 EATON ELECTRIC Variable frequency drive, 500 V AC, 3-phase, 12 A, 7.5 kW, ..
DA1-35012NB-B6SC
177017
Y7-177017
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller variable frequency drive regulates alternating current motor speeds across automated production lines to achieve optimal performance and energy conservation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 500 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 600 V
- Nominal output current I2N (EF009561): 12 A
- Power consumption (EF000346): 225 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Certified by UL for use in Canada
UL
UL Category Control No.: NMMS, NMMS7
CE
CSA-C22.2 No. 14
IEC/EN 61800-3
UL File No.: E172143
CUL
EAC
RoHS, ISO 9001
RCM
UL 508C
IEC/EN61800-3
IEC/EN61800-5
Safety: EN 61800-5-1: 2003
UL report applies to both US and Canada
Specification for general requirements: IEC/EN 61800-2
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
PROFIBUS, optional
PROFINET, optional
DeviceNet, optional
OP-Bus (RS485), built in
CANopen®, built in
Ethernet IP, optional
EtherCAT, optional
Modbus-TCP, optional
IP66
Breaking resistance
Control unit
Brake chopper
PC connection
OLED display
IGBT inverter
Local controls
Additional PCB protection
PROFIBUS
MODBUS
DeviceNet
CAN
PROFINET IO
EtherNet/IP
TCP/IP
Climatic environmental conditions
Max. 1000 m
Max. 4000 m
Main circuit
136 W at 100% current and 50% speed
163 W at 100% current and 90% speed
86 W at 25% current and 0% speed
86 W at 50% current and 0% speed
88 W at 25% current and 50% speed
88 W at 50% current and 50% speed
96 W at 50% current and 90% speed
Optional: Vector control with feedback (CLV)
Speed control with slip compensation
Sensorless vector control (SLV)
600 V AC, 3-phase
600 V AC, 3-phase
LPJ fuse used together with J60060-3 fuse base, Power wiring, Assigned switching and protective elements
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit