View larger
DA1-34061FB-B20C 197496 Y7-197496 EATON ELECTRIC Frequency inverter, 400 V AC, 3-phase, 61 A, 30 kW, IP20/NE..
DA1-34061FB-B20C
197496
Y7-197496
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Identified by part reference DA1-34061FB-B20C, this Eaton Moeller frequency inverter provides reliable speed and torque regulation for three-phase industrial motors.
Engineers deploy frequency converters throughout manufacturing systems to govern process speeds, lower mechanical strain, and improve overall system efficiency. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 61 A
- Power consumption (EF000346): 840 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS, ISO 9001
UL
UL 508C
UL File No.: E172143
UL report applies to both US and Canada
IEC/EN61800-3
RCM
Safety: EN 61800-5-1: 2003
UkrSEPRO
IEC/EN 61800-3
IEC/EN 61800-2
UL Category Control No.: NMMS, NMMS7
Certified by UL for use in Canada
CUL
EAC
IEC/EN61800-5
General
200 m, screened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
C2 ≤ 5 m, maximum motor cable length
100 m, screened, maximum permissible cable length
200 m, unscreened, with motor choke, maximum permissible cable length
Ethernet IP, optional
DeviceNet, optional
PROFINET, optional
Modbus RTU
EtherCAT, optional
PROFIBUS, optional
SmartWire-DT, optional
OP-Bus (RS485)
Modbus-TCP, optional
Yes
NEMA Other
Additional PCB protection
Radio interference suppression filter
Internal DC link
PC connection
Control unit
Brake chopper
Breaking resistance
IGBT inverter
OLED display
DeviceNet
CAN
TCP/IP
MODBUS
Other bus systems
PROFINET IO
EtherNet/IP
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
330 W at 25% current and 50% speed
330 W at 50% current and 0% speed
360 W at 50% current and 50% speed
390 W at 50% current and 90% speed
550 W at 100% current and 0% speed
670 W at 100% current and 50% speed
790 W at 100% current and 90% speed
Speed control with slip compensation
Optional: Vector control with feedback (CLV)
Sensorless vector control (SLV)
480 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 100 % (DC)
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit