View larger
DA1-32072FB-B20C 197491 Y7-197491 EATON ELECTRIC Frequency inverter, 230 V AC, 3-phase, 72 A, 18.5 kW, IP20/..
DA1-32072FB-B20C
197491
Y7-197491
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A frequency inverter like the Eaton Moeller DA1-32072FB-B20C provides precise rotational speed regulation for three-phase industrial motors. These electronic devices alter input power frequency and voltage parameters to control machinery acceleration, deceleration, and operational throughput.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 72 A
- Power consumption (EF000346): 518 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
EAC
IEC/EN 61800-3
UL report applies to both US and Canada
IEC/EN61800-3
UkrSEPRO
CUL
RCM
IEC/EN 61800-2
UL File No.: E172143
UL
Certified by UL for use in Canada
Safety: EN 61800-5-1: 2003
RoHS, ISO 9001
IEC/EN61800-5
UL 508C
UL Category Control No.: NMMS, NMMS7
General
150 m, unscreened, maximum permissible cable length
200 m, unscreened, with motor choke, maximum permissible cable length
200 m, screened, with motor choke, maximum permissible cable length
C3 ≤ 25 m, maximum motor cable length
100 m, screened, maximum permissible cable length
CANopen®
SmartWire-DT, optional
Ethernet IP, optional
OP-Bus (RS485)
PROFINET, optional
EtherCAT, optional
DeviceNet, optional
PROFIBUS, optional
Modbus-TCP, optional
In conjunction with DX-NET-SWD1 SmartWire DT module
NEMA Other
OLED display
PC connection
IGBT inverter
Brake chopper
DC link choke
Internal DC link
Additional PCB protection
Control unit
Breaking resistance
Other bus systems
EtherNet/IP
MODBUS
CAN
TCP/IP
PROFIBUS
DeviceNet
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Max. 1000 m
Main circuit
260 W at 25% current and 50% speed
280 W at 50% current and 0% speed
370 W at 50% current and 50% speed
510 W at 50% current and 90% speed
650 W at 100% current and 0% speed
760 W at 100% current and 50% speed
870 W at 100% current and 90% speed
Sensorless vector control (SLV)
Optional: Vector control with feedback (CLV)
Speed control with slip compensation
230 V AC, 3-phase
230 V AC, 3-phase
Motor rating
Apparent power
Braking function
Adjustable to 100 % (DC)
Max. 30 % MN, Standard - Main circuit