View larger
DA1-32060FB-B20C 197490 Y7-197490 EATON ELECTRIC Frequency inverter, 230 V AC, 3-phase, 61 A, 15 kW, IP20/NE..
DA1-32060FB-B20C
197490
Y7-197490
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A frequency inverter like the Eaton Moeller DA1-32060FB-B20C regulates electric motor performance by converting fixed incoming electrical frequencies and voltages into adjustable output levels. Industries utilize these units to achieve smooth acceleration, precise positioning, and improved energy efficiency across a wide array of heavy machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage: 200 V
- Mains frequency: 50/60 Hz
- Number of phases input: 3
- Number of phases output: 3
- Max. output frequency: 500 Hz
- Max. output voltage: 250 V
- Nominal output current I2N: 60 A
- Power consumption: 345 W
- Relative symmetric net frequency tolerance: 10 %
- Relative symmetric net voltage tolerance: 10 %
- Number of analogue outputs: 2
- Number of analogue inputs: 2
- Number of digital outputs: 2
- Number of digital inputs: 5
- With control element: Yes
- Application in industrial area permitted: Yes
More info
▲General specifications
UL Category Control No.: NMMS, NMMS7
IEC/EN61800-3
IEC/EN 61800-3
Certified by UL for use in Canada
Safety: EN 61800-5-1: 2003
UL
UL report applies to both US and Canada
CUL
CE
IEC/EN61800-5
EAC
RCM
UkrSEPRO
UL File No.: E172143
IEC/EN 61800-2
RoHS, ISO 9001
General
C2 ≤ 5 m, maximum motor cable length
200 m, screened, with motor choke, maximum permissible cable length
150 m, unscreened, maximum permissible cable length
200 m, unscreened, with motor choke, maximum permissible cable length
C3 ≤ 25 m, maximum motor cable length
SmartWire-DT, optional
CANopen®
Modbus-TCP, optional
PROFINET, optional
EtherCAT, optional
DeviceNet, optional
Ethernet IP, optional
OP-Bus (RS485)
Modbus RTU
In conjunction with DX-NET-SWD1 SmartWire DT module
NEMA Other
Additional PCB protection
Brake chopper
Internal DC link
Radio interference suppression filter
Breaking resistance
OLED display
PC connection
IGBT inverter
DC link choke
EtherNet/IP
PROFIBUS
MODBUS
PROFINET IO
TCP/IP
DeviceNet
CAN
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 4000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
240 W at 25% current and 50% speed
260 W at 50% current and 0% speed
330 W at 50% current and 50% speed
390 W at 50% current and 90% speed
480 W at 100% current and 0% speed
590 W at 100% current and 50% speed
720 W at 100% current and 90% speed
Optional: Vector control with feedback (CLV)
Sensorless vector control (SLV)
Speed control with slip compensation
240 V AC, 3-phase
230 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Adjustable to 100 % (DC)