EATON - MOELLER D02-LTS/63/3-R-HK D02-LTS/63/3-R-HK 114318 Y7-114318 EATON ELECTRIC D02-LTS/63/3-R-HK View larger
Images are for illustrative purposes only. Please refer to data sheet for details

D02-LTS/63/3-R-HK 114318 Y7-114318 EATON ELECTRIC D02-LTS/63/3-R-HK

D02-LTS/63/3-R-HK

114318

Y7-114318

EATON - MOELLER

1 Pcs.

D02-LTS/63/3-R-HK Eaton xEffect SASY 60i Enclosures Switch- & Controlgear Enclosure. Bus-mounted switch-disconnector with fuses, 63A, 400 V, 3p, D02, HK The flash function indicates the blowing of fuse link, delivery empty, without adapter sleeves and fuse links, retaining springs for D01 fuse links or cylindrical fuse links 10x38 supplied, contact position indicator, fuse plug without screw cap, switches the load on all poles and without touching by hand, version D02-LTS/63/3-R-HK with integrated auxiliary contact, sealable and lockable

Connectors > D0-system switch disconnector
Connection Accessories for Enclosures

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton xEffect SASY 60i busbar system device D02
Catalog Number
114318
Model Code
D02-LTS/63/3-R-HK
EAN
4015081137183
Product Length/Depth
226 mm
Product Height
102 mm
Product Width
27 mm
Product Weight
0.361 kg
Compliances
RoHS conform
Certifications
IEC/EN 60947-3

Delivery program

Type
Amperage Rating
63 A
Number of poles
Three-pole

Technical data - electrical

Voltage rating
400 V AC
Rated operational voltage (Ue) - max
400 V
Rated impulse withstand voltage (Uimp)
6 kV
Rated operation current (Ie)
63 A
Rated conditional short-circuit current tested with links
63 kA
Conventional thermal current ith of auxiliary contacts (1-pole, open)
63 A
Current heat loss per contact at Ie
1.5 W
Frequency rating
40 Hz - 60 Hz
Frequency rating of contacts
40 Hz - 60 Hz
Utilization category
AC-22 B
Overvoltage category
IV
Pollution degree
3

Technical data - mechanical

Enclosure width
226 mm
Frame
E18, D02, C10x38
Mounting position
Vertical or horizontal
Mounting width
27 mm per pole (1.5 space units)
Degree of protection
IP40 enclosed
Distance between busbar centers
60 mm
Terminals
Lift terminals
Terminal capacity (solid cable)
1.5 mm² - 35 mm² at box terminal
Construction size
D02
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Design verification as per IEC/EN 61439 - technical data

Heat dissipation per contact with fuse link at Ie
7 W
Permitted heat loss from fuse links - max
5.5 W
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C

Additional information

Functions
Busbar fuse material
Uninterrupted operation (Control mode)
D fuse switch-disconnector with flashing function
Special features
  • The flash function indicates the blowing of fuse link
  • Supplied empty, without adapter sleeves and fuse links
  • Retaining springs for D01 fuse links or cylindrical fuse links 10x38 supplied
  • Contact position indicator
  • Fuse plug without screw cap
  • Switches the load on all poles and without touching by hand
  • with integrated auxiliary contact
  • Sealable and lockable
Used with
25 mm x 5/10 mm rail
30 mm x 5/10 mm rail
15 mm x 5/10 mm rail
Double T profile
20 mm x 5/10 mm rail
12 mm x 5/10 mm rail
60 mm system
185 mm system

ETIM for 114318 Circuit breakers and fuses (EC000277)
Feature Name Feature Value
Number of poles (EF001391) 3
Construction size (EF002566) D02
Rated voltage (EF000228) 400 V
Rated current (EF000227) 63 A